Free Home Air Conditioning!
Save Money on Your Electric Bills!

Imagine if you happened to live directly over Mammoth Cave in Kentucky. Down below you, on a 95ºF hot summer day, there was all kinds of 56ºF air down in the cave! So imagine that you bored two large holes down from your house into the ceiling of the cave. You would then be able to use a standard furnace blower to draw air up one, to push it into the house through your existing heating/air conditioning ducts and registers. The second duct would be to allow your hot house air to go back down into the cave to replace the cool air you removed. Presto! You have awesome air conditioning!

Well, that general concept will work in most climates, if an "artificial cave" is created deep in the ground under your house. Note that there is nothing complicated or complex about this idea, it is actually really simple, and even obvious! All we did was to apply modern Engineering methods to calculate how to make an "artificial cave" that is most efficient. We also found a way to use really inexpensive materials that are already available in a store near you!

Actually, we even make an improvement over that idea involving a natural cave, because it turns out that a natural cave could foul up the humidity (IRH) in the house. So the system presented here (which is a sealed, recirculating system where the house air is actually never mixed or exchanged with any other air, essentially duplicating a modern heating or air conditioning system which has air return ducts) is even better than what was just described!


Using ONLY locally available materials, it is possible for ANY homeowner to virtually eliminate their electric bills for air conditioning FOREVER! If a million California homeowners would choose to individually save this money, they would collectively reduce the electricity power load on the California power grid by around 5,000 Megawatts! That reduction might even help the electricity suppliers keep up with their demand! A grass-roots solution for a problem that the honchos can't solve!

This is a method for supplying plenty of cooled, de-humidified air for almost any house or many commercial buildings, WITHOUT needing to run an electricity-eating air conditioner compressor! Even better, it is fairly inexpensive to install and unbelievably environmentally friendly! All of the rooms of a house will be EXACTLY as comfortable as if that expensive compressor was running! The temperature, humidity and comfort level can even be regulated by the very same wall thermostat you already have!

This system is extremely logical and actually very simple. It involves moving the house's air through large tubes (like tunnels) underground. In technical terms, these tubes are "heat exchangers" that use long-proven simple techniques to transfer heat FROM the house air INTO the cool deep soil.

The temperature a few feet down in the ground is remarkably constant throughout the day and year. In Chicago, for example, that deep soil remains approximately 52ºF, day and night, summer and winter. In the summer, the hot house air is blown through some underground tubes and that hot house air is cooled by contact with the cool (52ºF) walls of the underground tubes. It turns out that it is also de-humidified, too! It turns out that IF the soil happens to be at 60ºF, when the house air is cooled to that temperature, the relative humidity in the tubes rises to 100% and moisture in the air condenses out on the walls of the tubes. When that 60ºF air at 100% moisture is again raised to the desired 76ºF air temperature in the house, the humidity (called IRH) is at the desired 40%. If the soil is cooler than 60ºF then the air is pushed through faster so the humidity is not lowered too much. If the soil is above 60ºF, a separate dehumidifier is likely to be necessary.

By the time the air has returned to the house, it is then exactly the same as the cooled air that would have come out of a standard central air-conditioner. Air conditioning is accomplished without running an energy-expensive compressor, virtually eliminating air-conditioning expense. In the winter, there is even a bonus effect which can be provided pretty easily! Make-up air for the house, that might sometimes enter the house at -10ºF, would enter the house at around 52ºF instead! The heat load of the house can be significantly reduced, minimizing heating bills.


Have you ever been in a cave? Remember how cool it was, even if it was 90ºF outside? The air inside that cave that you were breathing did not start out in the cave. Some winds had blown air in through some opening somewhere. Hot outside air that had gone into the cave had been cooled by the cool walls down there. That's pretty much what we are doing with this system. You can do this with locally available materials, which should cost on the scale of $500, in just a day or two, which would mostly be digging up and refilling trenches across your yard! If you hire a backhoe or trencher to do that might be another $500. Adding in some other expenses, the whole works might be do-able for well under $2,000. (These estimates depend on house size, climate and other factors, and are suggested as a ball-park estimates.) Simple, easy, fairly inexpensive, perfect!

WHY is a cave cool like that? It is actually very simple and logical. In the summer, you get a lot of heating and in the winter a lot of cooling. For YOUR climate and location, there is some "average annual temperature". THAT is the natural temperature of the deep ground where you are, no matter WHERE you are! As it happens for Chicago, summer temperatures are generally around 72ºF and winter around 28ºF (average day/night), and halfway between those is around 50ºF, which happens to be the deep soil temperature. It is NOT a coincidence!

Below, we provide a map of the US which shows the measured well water temperatures, which generally accurately reflect this annual average temperature. For other countries in the world, it is easy to get a pretty good idea of this number. Just find the daily average temperatures throughout the year and average them. Here are a few examples:

CityMarJunSepDecAverage
Chicago36ºF72ºF66ºF28ºF50.5ºF
Berlin39ºF64ºF59ºF34ºF49.0ºF
Paris45ºF63ºF61ºF39ºF52.0ºF
Madrid50ºF69ºF68ºF42ºF57.3ºF
Beijing39ºF75ºF64ºF25ºF50.7ºF
New Delhi73ºF94ºF85ºF60ºF78.0ºF
Calcutta82ºF87ºF85ºF69ºF80.7ºF
Riyadh69ºF93ºF89ºF61ºF78.0ºF
Jakarta81ºF81ºF81ºF80ºF80.7ºF
Manila81ºF83ºF81ºF78ºF80.7ºF
Montreal28ºF66ºF60ºF21ºF43.7ºF
Lagos82ºF78ºF77ºF80ºF79.7ºF

The European cities shown here would have excellent performance of this system, as their annual average temperatures, and therefore their deep soil temperatures, are in the low 50ºsF. The cities that have deep soil temperatures around 80ºF would have no way to cool house air down to a desired 76ºF! Probably around 85ºF is the best they could hope for, if that were acceptable, but in a linked page, we discuss using this system in very hot climates to pre-cool the house air such that a conventional A/C might have to work less to save some money. So this system DOES have some limits!


By being able to entirely and continuously cool a house all summer, without a compressor running, many homes could save $1,000 or more, EVERY summer! This is certainly a great thing for the homeowner, who has to pay the bills, but it can also help many energy-strapped utility companies. If a substantial number of people would install this system, the summer electricity demand could be substantially reduced.

Does it GET any better than this? You SAVE $1,000 (or more) every year for the rest of your life. You have a cooling system that is unbelievably environmentally friendly. AND you're helping the short-sighted electric companies past their crisis. And all this does not even cost an arm and a leg! (Maybe a toe or two!) There are a lot of variables, like home size, climate, soil type, etc, but a do-it-yourselfer could put the whole system in for under $1,000 for some houses. (Contractors would charge more, but probably still a manageable cost.)


Warning! This presentation is VERY long and sometimes more technical than many people are comfortable with! Sorry about that! But there are some rather stupid ideas being presented that resemble this concept, and we want people to be able to get actual good performance from this system, so we feel the need to try to make sure that people do not confuse this with systems that use tiny buried pipes or coils or such things! So IF you like this concept but cannot swallow all the technical stuff here, there must be some relative or neighbor who loves technical stuff that you can dump this on to see if it can be used by you! That person might even LIKE Psychrometric Charts and such things!


Some Technical Stuff

There is a somewhat similar energy source called Geothermal Energy. That is actually different from the energy involved in this device. Geothermal energy taps energy that is coming upwards from the hot center of the Earth. Most geothermal energy applications involved rather deep wells or a location near natural hot springs. This system does not need that energy source. Most of the energy involved in this system is actually solar energy, which had arrived months earlier and became stored in the mass of the earth, just a few feet deep.

Each location on Earth has a certain annual energy input from the Sun and a certain energy loss from radiation (into space), conduction and convection. In the long-term, these two must be identical.

The consequence of this is that Equatorial locations, which receive more solar energy during a year, must necessarily have a higher average ground temperature in order to radiate, conduct and convect that greater amount of incoming heat away. Polar regions have colder earth for the same reason. Very near the surface, the ground temperature is greatly affected by day and night and summer and winter, but even three feet deep, those effects are fairly minimal. If you go down to twelve feet deep, the summer-winter differences are generally under 1ºF, and they tend to lag several months behind the seasons.

Here is a map of the US showing average deep soil/well temperatures. Just find your location. The usual indoor design air temperature for air conditioning is 76ºF, so if the deep soil in your area is under 76ºF, this approach can work! This system needs to have several degrees of temperature differential to drive the heat exchange processes, with around 5ºF usually being sufficient, so a deep soil temperature of 71ºF or lower is best for the best performance. (Even if it was above, house air could be substantially cooled, reducing the need for a central air conditioner to work, STILL saving you a lot of money!)

This technology is being GIVEN away, FREE. Beginning in November, 2000, we have tried to get word out to California homeowners that this option is available to each of them. It is given in the spirit of one human being helping a neighbor.

We are just trying to offer assistance for people who seem to be destined for some great adversity. We have heard that in San Diego, electric rates quadrupled in 2000. People who paid out $1000 the previous year for a summer of air conditioning are amazed at their recent bills for this and all following summers! And the electric companies have basically confirmed that blackouts will occur for up to ten years, until they have enough new power plants built.

How could caring people NOT offer a solution where none other seems to be available? But the response has been amazing. The bulk of officials and politicians seem to assume that if this had any value, we would certainly be trying to make piles of money on it, so they are polite, but clearly cannot wait until the conversation is over.

Some California homeowners DO seem to be aware of upcoming problems, but they seem to almost universally believe that there really IS no shortage and that this whole fiasco is some ploy on the part of the power companies to be allowed to charge them more. And, they have been conditioned so totally that government and executives can solve all of their problems, that most seem willing to patiently wait until government somehow bails them out of whatever "minor" inconveniences they will face.

These problems ARE very real. Yes, they seem to have been made far worse by greedy businessmen and poor bureaucrats, but the problems exist. It seems certain that those many people are going to be very upset as they realize the severity of the problem, AND that they probably face similar or worse problems for the next nine years!

At whatever point any homeowners feel the need to solve their own problems, on a grass roots level, this page should be here. It is, and forever will be, offered as a Public Service.

No incredible breakthrough is presented here. The concepts have been known for many decades. I heard a rumor that even the ancient Romans "air conditioned" a few buildings with this method (but I doubt it!) Our primary contribution is to figure out a system that only costs on the order of one or two thousand dollars and which would probably save the homeowner more than that outlay every single year, forever.

We have a single request. The fact that we are giving away a pretty thorough explanation of this system, does NOT mean that we are also offering unlimited free engineering expertise as well! For unusual houses, or ones in unusual locations, or in especially hot climates, it is sometimes prudent to have individual engineering calculations done, to ensure proper performance. Any local engineer (HVAC, civil, mechanical, chemical, etc) should be able to do the necessary calculations. If they (or you) wish, we can provide all the necessary technical equations (and examples) for such analysis, (the Technical Packet) which anyone that understands algebra should be able to use. Since November 2000, we have required that a person make an anonymous donation of $250 to any Charity, Church, Soup Kitchen, etc, and then we have provided the Technical Packet. (We have never required any receipt or proof beyond the person's word.) Details are in a link below.

We feel that most houses in most climates do NOT need this extra engineering effort!

C.

Map of the US showing average deep soil/well temperatures
Actually, the temperatures shown here are nearly always very close to the average of the summer and winter average temperatures. (In Chicago, the average December temperature is 28ºF and the average June temperature is 72ºF, which averages to 50ºF, close to what this map shows.)


There happens to be another approach that is relatively similar to ours, which is often incorrectly called a geothermal system. It is a variation of a standard heat-pump that uses ground water (usually well water) or occasionally buried copper tubing to capture the same energy we are going for. Such ground-sourced or water-sourced heat pumps have been long proven and sold, and are very successful at providing heating and cooling for many homes. They represent one of several "proofs" that our system works. Such ground-source heat-pumps are NOT the same, though, because they still need to have and run a compressor, so even though they have some advantages over conventional A/C, they only have SOME! (However, their compressor allows them to provide some amount of winter heating, by "boosting" the heat that exists in the ground, which our approach cannot do.)

Heat-pumps are much more efficient than normal air conditioners, but they still have compressors that use a lot of expensive electricity. Because they use that compressor, they have the capability of sort of "multiplying" the heat/cool from the ground to even provide complete winter heating (for some mild climates), where our system, without a compressor, does not try to accomplish that. But we don't have to pay for electricity for that compressor, either!


As cooling or heat is removed from the deep ground in our system (or in a ground-source heat pump), it is gradually replaced primarily by heat conduction from nearby soil, through the soil. It turns out that many soils are pretty lousy at conducting heat in this way, so this replenishment tends to be fairly slow and nearly always represents the limiting factor in the long-term operation of this system. In areas where the soil is saturated with water, some convection can occur, too. Therefore, if the deep soil is moist, this system works tremendously better. Water-source heat pumps nearly totally rely on this convection effect.

Because any substantial volume of earth contains enormous amounts of heat/cool storage but the many soils are so poor at heat conduction, the AREA of the interface (tube wall) between the soil and the tube contents nearly always is the greatest limiting effect on short-term system performance. Ground-source heat pumps generally have very small diameter copper tubing, so the circumference and the outside surface area in direct contact with the soil is very limited. This tends to make ground-source heat pumps to often act like they have depleted the energy source very quickly. Fortunately, they have their compressor that just has to work harder, but can still continue to work during fairly severe depletion. And, in any case, energy from nearby soil replenishes the energy source in just a few hours.

Our approach is to use much larger diameter tubing underground, which greatly increases the contact area between the soil and the tubing surface. This total "area of contact" is one of the most important characteristics to design for in this system! Again, in more technical terms, heat exchange is proportional to the surface area of the heat exchanger. It determines the amount of heat (or coolness) that can be given to the house air that is flowing through the tubes, in other words, the Btu/hr rating of the system (or short-term performance). Even normal ground-source heat pumps would benefit from such a larger surface contact area, but their compressor allows designers to calculate very minimal systems, to keep their digging (and copper tubing) costs at a minimum.

Further, our approach is to divide the underground air passageway into several "parallel" paths, separated from each other by around six horizontal feet. This configuration takes into account the very slow soil heat conductance and yet allows using a FAR larger mass of soil to participate in this system, which determines the long-term performance of the system.

Drawing of a compact arrangement of the underground tubes.
This drawing suggests a very compact arrangement. For example, if a 50 by 50 foot area of yard was involved (about 1/16 acre), nine parallel tubes (six feet apart, or 48 feet across all of them), and each 50 feet in functioning length as shown, a total of around 450 feet of functional tube length would dissipate house heat into the soil. You would probably need around double that amount of the sewer pipe, since they are "bundled" together on their way to and from the building, as the small cross sectional drawing shows. Our drawing does not show the three (or more) identical tubes above the top of the drawing This arrangement would represent a way of installing around 500 lineal feet of heat exchange surfaces in that fairly compact area (counting the bundles). Such a configuration makes sure that one or another of the tubes is within three feet of well over a million pounds of cool soil. (Simple engineering calculations show that that much soil represents over 10,000,000 Btus of cooling available!)

In case you are curious, we chose bundling all the tubes together on the way to the house as the simplest and least expensive way to join the tubes and also make sure they are all watertight. Other, better ways exist, where the bundles are replaced by large ducts, and especially tapered ones, to make sure that the same amount of air goes through each tube. All such ways that we know of are very expensive to do! So even though the bundling approach has some disadvantages, it is reliably sealable to be water-tight/air-tight, fairly simple and easy to install, and fairly inexpensive. For the technical ones out there, yes, we intentionally over-designed the generic system to account for the different amounts of air flowing through the different length tube air paths!

In case you're still skeptical, the "heat exchanger" arrangement we are describing has a coefficient U that is around 8 Btu/hr/square foot/ºF difference. If you look at ONE of our nine tubes, its circumference is around one foot and it is 50 feet long, so its area is around 50 square feet. If the house air begins at 90ºF and the deep soil temperature is 53ºF, there is 37ºF difference. Multiplying these (8 * 50 * 37) gives an effective rating of 14,800 Btu/hr. That's ONE of our tubes, and there are nine of them! This suggests that the total system is capable of about 135,000 Btu/hr cooling, around four times as much as the normal house requires! Well, it could (almost) actually do that for a few minutes, but there are a number of factors that would get it down below 100,000 Btu/hr of cooling in under an hour and within a few hours to the 36,000 Btu/hr that we designed our "standard configuration" for.

Many larger houses and hot climates should probably have specific engineering done to determine that that is enough, but this system's million pounds of cool soil would often be sufficient for many houses and climates.

Basically, we are using modern engineering concepts to maximize the effectiveness of a natural phenomenon!

There are many variables involved, but many installations should be able to use 4" plastic (thinwall) PVC drain/sewer pipe, available at any local 'home' store. (Technical Comments). At around $3.50 per ten-foot length, the 900 feet of pipe mentioned above (90 lengths) and a bunch of elbows would only cost around $350. A trencher (sort of like a roto-tiller) can be rented for around $220 per day. The sections are light and easy to handle, and available almost everywhere. Standard PVC Cement glues the sections together. A do-it-yourselfer could do this amazingly inexpensively and quickly and easily!

Materials List
90 pieces 4" PVC THINWALL sewer (ASTM D-3034) ~$316
18 pieces compatible PVC sewer elbows (ASTM D-3034) ~$36
a lot of PVC cement ~$15
Rental of DitchWitch
#1820 Trencher
~$220
The drawing above certainly does not show the only possible arrangement. But it shows a compact arrangement with the three important considerations.

  1. There is a lot of total pipe surface area (which defines the short term performance of the system). In this case, there is over 500 square feet of exterior pipe surface in contact with the soil. Even though PVC pipe does not have the thermal conductivity of aluminum or copper, it turns out that that fact is of minimal importance (because the soil is so much worse!) And PVC sewer pipe is, could we say, "dirt" cheap???
  2. Pipes are distributed so that a lot of mass of soil is within about three feet of some tube (which defines the long term performance of the system), (in this case, around 2.1 million pounds) and
  3. The AREA of the air path always totals an area comparable to the area of the main house ducts (which allows proper airflow through the whole system and house). In this example, each 4" tube has around 13 square inches of cross-sectional area, so 9 of them total about 120 square inches, fairly similar to an 8" by 16" house trunk duct of 128 square inches. If the house has larger main ducting, then more tubes should be "bundled" together, like 3x4 (12 tubes or 156 total sq.in.) or 4x4 (16 tubes or 210 total sq.in.) We could describe this in a different way. A 4" diameter tube can realistically carry around 60 to 80 cfm (cubic feet per minute) of air through it. Nine of them in "parallel" can therefore carry around 700 cfm, 12 can carry around 1,000 cfm, and 16 can carry around 1,300 cfm of total airflow. Conventional A/C units generally have greater airflow rates than this, but it is actually because their performance is poorer at slower airflow rates, and the house does not actually need that great an airflow. In fact, that same central A/C/furnace uses far less airflow during heating in the winter! The total airflow rate is mostly related to the comfort level inside the house, regarding how well the cooled (or heated) air is distributed to all rooms and to corners of those rooms.

    This is mentioned here because we have been told by a lot of people that they intended to "customize" or "improve" our system! One man said he intended to run ONE extremely long tube (around a mile long underground, as I recall) instead of our 9 or 12 or 16. He certainly would have cooled the air down, but would have caused himself two new problems! (1) No matter how powerful a blower he would use, that one tube would only be able to supply 60 or 80 cfm of that cooled air to his house! That is enough for a small bedroom, but no more! (2) Whatever blower he would have tried to use, that blower would have to be extremely powerful, probably several horsepower, because it would have to be constantly be pushing that entire mile of air inside the tube! He likely would spend more for all the electricity needed than he would save on A/C bills!

    There have been (many) other people who have said they intended to only install four tubes (mostly to save on the cost of digging the trenches) and they figured that was an "improvement". Note again that such an installation would likely only provide around 300 cfm of cooled air to the house. That is certainly enough to nicely cool two or three rooms, but not really enough airflow to give the comfort level that we spoiled Americans expect for a whole house!

If you do a reasonable job of providing these three considerations, your system is bound to work! But please don't "improve" it unless you really know what you are doing!

(Alternate Configurations).
(More Technical Comments).


(Information Regarding Inside the Building).
Here are some recent additional versions of this system.

Virtually all of the heat that replenishes this system (or ground-source or water-source heat pumps, close cousins) originally began as solar energy that heated the surrounding fields, often months before. Virtually no actual "geothermal" heat is involved. However, there is no commonly accepted name for this process and we suspect that it will generally be thought of as geothermal heating/cooling. Oh, well!


In case you are curious, this system was invented and designed by a nuclear physicist! It is based on very well established processes and we refined it with Engineering, as a sub-system which was initially designed and Engineered as part of our NorthWarm Version 1 Solar heated House. Where other people who try to do solar heating ONLY think of the heating part, our system is over-designed (to always provide plenty of solar heat to entirely heat the house 100%) but that then required the addition of the capability of providing air conditioning to ensure the comfort of the occupants at all times!

This article is presented separately from the Solar System presentation because this feature could be added to most houses, either while they are being built or to be retrofitted later to existing houses. This sub-system can be fairly inexpensive and can be configured to completely eliminate ALL conventional summer air conditioning usage (and those huge electric bills!) In the winter, the same system significantly reduces home heating cost by reducing the necessary heat load. Yet another benefit is that recent Indoor Air Purity concerns can be addressed in a way that is not costly or wasteful. Finally, you cannot get much more environmentally friendly than this system!

Now, you probably already see the obvious logic of this system. Some fairly large-scale (expensive) systems have been occasionally installed for at least 30 years, and the relatively similar ground source heat pump system has been marketed for twenty years, so the concept is well proven. We are just presenting a low-cost version of it for residential use.

You are probably curious if the designer of this system uses it! Actually, his house has an unusual environment, and he uses a variation of this system which required much more design engineering but works even better! Here is a description of it.


Essentially, this is why basements generally stay cool in the summer and why caves remain at very constant temperatures. In case you have any doubts, just find a long underground culvert (like under a highway) or aqueduct or cave and stand near the open end of it. If the wind happens to be blowing in your direction, you will feel a rush of very cool air coming out of it. That air had actually entered the other end at the 90ºF of the outdoor air and had been cooled in passing through that tunnel. That is essentially exactly what our sub-system does.

This might lead you to believe that no planning or engineering is actually necessary! Well, technically, you would be right! If you chose to bury a mile-long culvert, it would certainly work excellently! However, most people couldn't afford to do that! They would want the shortest, most compact arrangement possible, both to fit under their yard and to minimize the digging expense.

The example described above will work extremely well for most medium-sized homes in moderate climates. So, no additional engineering is necessary for such applications! But, where soil is extremely dry, or the climate is extremely hot, or the house is especially large, prudent design might involved extra engineering. There is even often an alternative here, too! OK! You make 4' deep trenches and place the PVC tubing in the bottom of them. Instead of immediately filling in the entire trenches, for such applications, consider filling in ONE foot deep of fill in the trenches! THEN, get (cheap) 100 foot-long coils of black polyethylene 1/2" water line from the store, and drill LOTS of small holes in it! Make water connections to this set of water pipes, which are now one foot above the much bigger air tubes below. THEN fill in the trenches and re-plant your grass.

IF the system should ever seem to lose effectiveness in the future, it would generally be because the soil had gotten too dry down there, and the coolness was not able to flow through the soil to the tube. By briefly running some water through those water lines, you can quickly saturate the soil around the air tubes, TREMENDOUSLY increasing the system's performance (often by over a factor of EIGHT!) This "accessory" to this system is really inexpensive to add, and if your climate or soil dryness or house size is even moderately unusual, it might be a good idea to add this feature, even if it turns out that you never need it.


If the system is not properly designed and planned, there are two possible problems. A too-small cooling system (not enough total surface area of soil to tubing or not enough actual total soil involved) might work really well for a while, but then the ground and tube would warm up, and could almost completely stop having a cooling effect, and you would have to wait a day or two to again get any cooling. The other potential problem has to do with safety concerns related to the water that would condense INSIDE on the walls of the cool underground tube, and that will be discussed below.

Comparison to Conventional Air Conditioning

We are not going to go into the actual operation of a standard air conditioning system, except to say that a compressor is necessary in the cooling process. Any textbook on air conditioning can explain the process. Most residential and commercial applications use electricity to run the compressor. THIS is where the problem is!

Let's say you have a moderate sized house in a moderate climate and you want to have 36,000 Btu/hr of cooling. Again, there are straightforward engineering conversion formulas that indicate that this is equivalent to about 10.5 Kilowatts of actual cooling effect. Our thoughtful government has provided us with a SEER (Seasonal Energy Efficiency Ratio) or COP (Coefficient of performance) for each air conditioning system sold. Let's say for a moment, that yours happens to have a SEER of 10 (about the same as a COP of 3.0). You would just divide the cooling load (36,000) by the SEER (10) to know how much electricity will actually be used (about 3.6 kW) of electricity. If you knew the COP instead, you would divide the cooling effect (10.5 kW) by the COP (3.0), or again, about 3.6 kW of electricity.

Most actual central air conditioners have a lower SEER than 10. Government studies have established that home central air conditioners average using 1.49 kW of electricity for the compressor and another 0.14 kW for fan motors, for each "ton" (12,000 Btu) of rating. Our example 36,000 Btu/hr system (3 tons) would therefore probably use about 4.9 kW of electricity (which calculates to a SEER of about 7.3).

Still with us? Now say you have a REALLY hot day, and the compressor ran virtually continuously for all 24 hours (not particularly good for the compressor!). You would have used up 4.9 * 24 or around 118 kWh of electricity that day. Look at your latest electric bill and it will tell you what each kWh costs you. Recently, electric rates have been going wild in many parts of the country. In an area where such rates are still relatively stable (Chicago), the rate is still only around 10 cents per kWh. One hundred eighteen kWh would therefore cost 118 * 0.10 or about $12. That single very hot day would have cost $12 in air conditioning. This is for a very moderate sized house and air conditioning system and for very reasonable priced electricity. We have shown you this logic here so you could figure these things out for YOUR system using electricity available to YOU.

You can probably now better understand the very large electric bills you receive during the summer. Twelve dollars for a hot day could easily account for $200 per month. Far more, for larger homes and for where electricity is more expensive than ten cents per kilowatt-hour.

The system described here does not involve any compressor! The only electricity necessary is for a fan or blower to push the house air through the underground tunnels! In many cases, this can be accomplished with a fan or blower that only uses 200 watts (0.2 kW) or less of electricity. In terms of SEER, the effective rating would be (36,000/200) around 180! That's nearly TWENTY TIMES as energy efficient as the very BEST heat pump or air conditioning system!

On that example very hot day described above, let's look at the figures. Instead of continuously using up 4.9 kW of electricity, this system only needs 0.2 kW. In 24 hours, that's 4.8 kWh. At the electricity cost mentioned above, that's $0.48 of electricity instead of $12.00! A full month of such heavy cooling would cost around $10 instead of over $200!

There are actually even some possibilities of eliminating the cost of running the fan, too, eliminating even that last $10 of monthly operating expense! However, it is such a minimal remaining expense, it is probably not worth even trying to do that!

This basically states the point of this system (regarding air conditioning). If you have a moderate sized house in a moderate climate and you have moderate electricity costs, you are STILL likely to sometimes save $200 in a single month! In a whole summer, this "eliminating" of the cost of air conditioning the house or building, might easily save you $1,000. Basically, whatever your total electric bills were last summer, inflated for the recent price hikes, THAT'S what you would save! And, that savings would be EVERY year, for the rest of your life! What a deal!

In areas where electricity costs have drastically risen in recent months, they are not likely to ever fall back to where they were. Using the logic presented above, you should be able to figure out approximately how much air conditioning will cost you. Or just check the electric bills from a previous year and multiply by how much the cost of electricity has multiplied. We are guessing that there are many millions of homeowners who are going to find it no longer possible to regularly air-condition their homes, just because of this tremendous increase in the cost of electricity. Well, that's a main reason we are presenting and offering this page! Each homeowner who would install this simple and obvious system, will virtually certainly save more than $1000 every summer (depending on climate, of course), forever! If a new monthly TOTAL cooling cost becomes only $10, even if it some day doubles, that's only $20!

And the coolest (pun intended) part of this is that all of the comfort in the house is PRECISELY identical to that when using conventional air conditioning. The temperature and humidity levels will be identical. Of course, you would not have a noisy condenser unit running outside your house, so if you like that sound, you're outa luck! All this, in a system is about as "natural" as you can get! And bonus $$$ savings in the winter!

If you live in ANY house, and YOU pay the electric bills, you must now see the exquisite logic of this system. It even has a bunch of additional bonus characteristics. For example, there is virtually NO chance of ever being charged for any repairs to the system, because there is virtually nothing that could ever break or fail or leak!

It seems to us that such homeowners will even be doing good things for society and the environment, as well as pocketing an extra $1,000+ each year. Consider California and its amazing energy woes, particularly electricity. Even during the winter, their electric companies and power grid have great difficulties in keeping up with electrical demand. Consider if a million California homeowners decide to save $1,000 each, every summer, with this type of system. They're smiling! LOTS of happy people in California! But consider this! If a million California homeowners are NOT taking 5 kW each from the power grid during the summer, that's a reduction of load on the power grid of FIVE THOUSAND MEGAWATTS! It is unclear if that would "solve" the lack of planning of California's electricity needs, but it would have to help!

(I know! I know! There are far too many exclamation marks in the previous paragraphs! But several of these concepts are pretty amazing! Huh?!)

Winter Make-Up Air

All buildings have a certain amount of infiltration, air that somehow leaks into the house. Necessarily, an equal amount of air must also leak out of the house. In any heated building, the infiltration air tends to be low in the building's walls and the exiting air tends to leave high on the walls or through the roof. This is a result of natural physical laws. During air-conditioning, the process is reversed.

Until around 1985, all houses built had significant infiltration (leakage), and many thousands of cubic feet of heated house air would therefore leak out each hour and be wasted. This added considerably to the heating load of the house or building, but it actually naturally assured indoor air purity because any air seldom actually remained in the house more than an hour or two.

After some energy shortages in the late 1970s and early 1980s, houses were built to be extremely tight, because of this very situation. Air infiltration was nearly eliminated. This significantly improved the energy efficiency of the house, but it caused the air in the house to not have any way of ever leaving. Where the smell of a cigar would have left in an hour or two in an older house, it is now trapped for days or even weeks in the new, tight house.

This situation eventually caused great concerns regarding Indoor Air Purity. (It is amazing that no one saw that coming!) Not because any more pollutants were being created in the house, but because the ones created in the house could never leave.

By the middle 1990s, Building Codes were starting to add new rules, where motorized house pressurization or similar schemes were required in new construction. In a darkly humorous sense, they are defeating the entire advantage accomplished by making the houses so very tight only a decade earlier! Some States' new (bad) rules require motorized exhausters, which is a truly bad idea because it causes the house to be at negative atmospheric pressure. That could cause fumes from a car in an attached garage to be sucked into the house, or smoke from a fireplace drawn out into the room as air is sucked down the chimney, or paint fumes from a workshop in the basement be pulled upstairs. Others of the new rules, slightly more thought through, require a similar motorized device to forcefully inject fresh outdoor air into the house. In principle, this is a far better idea, since it slightly pressurizes the house. If any leakage would happen associated with a garage, it would be (warmed) house air being forced out into the garage. Regarding a fireplace, warmed house air would be forced up the chimney. Wasteful of heat, but not a source of Indoor Air Pollution.

By the way, this pressurization approach has existed in most large commercial stores for decades. Did you ever notice how air whooshes (outward) past you as you enter the door of such a store? That's actually unnatural, because the "chimney effect" tends to always suck cold outdoor air INWARD near the ground and it leaks out through cracks high in a building. They pressurize such buildings for several reasons, but that is one of them. They don't want their incoming customers to have to feel an incoming blast of cold outdoor air!

Amazingly enough, some of the new laws realized that a motorized pressurizer couldn't actually push any new (clean) air into the house unless old (stale or polluted) air was able to get out, so they ALSO required PERMANENT openings in the house where this air could leave. Some new windows are built with these permanent openings in the frames! In principle, those windows act like they always remain slightly open! It's sort of hilarious! The older laws mandate super insulation and all that (costing the owner $$$) to make the house more energy efficient. These new laws require expensive motorized blowers and special windows and such which are designed to completely defeat the purpose of the original added expense, only at additional expense! Only in America!

Our Approach

Given this last arrangement, it figures that most building codes will eventually require such house pressurization for every new home constructed. Hopefully, they will not be as wildly illogical as some present rules that require not only the motorized pressurizer but permanent openings for house air to be able to be pushed out of the house! The effect is of having a well-built energy efficient house, but with a window permanently open! Amazing!

Since some amount of outdoor air must then be brought into the house (by the motorized pressurizer), if the outdoor temperature is below zero, this adds greatly to the heating load for the house, and therefore to the cost of supplying heat for the house (unless you have the Solar Heating System!) In principle, you are bringing in extremely cold outside air and then having to add quite a bit of heat and humidity to it.

We're finally getting to our (winter) improvement! Assuming you have a large yard, imagine digging a trench about four feet deep all the way across the yard, and maybe then even zigzagging around the yard. In the bottom of this trench, place a large diameter pipe, and then fill the trench back in. At the one end of this pipe, have it pass through the basement wall and open into the basement or some other low part of the house. At the opposite end, (for primarily heating systems) have it elbow upwards so it sticks up out of the ground. (Make it decorative somehow!) (For primarily cooling systems, see below, and the descriptions earlier.)

The motorized pressurizer would be set up to draw its air through this long underground tube. When the air was first drawn into the tube at the outer end, that air might be below zero. But the ground several feet deep is much warmer. In the Chicago area, for example, it always stays around 52ºF. As the air was drawn through the long tube, as long as the tube was designed and dimensioned properly, it would pick up heat from the surrounding pipe and soil. By the time the air arrived at the house, it would have been (naturally!) heated from the original 0ºF to around 52ºF. Only a minor amount of heating would then be necessary to raise it to the 70ºF for the house, around 1/4 of that needed otherwise!

Summer Air Conditioning

This underground tube concept is REALLY beneficial during the summer! The deep ground is still around 52ºF in Chicago in the summer. Rather than using an electrical air conditioner, which is pretty expensive to operate, why not make BOTH ends of that underground tube come through the basement wall? Then, use the existing air handler or furnace blower to push the house air through this tubing. The hot house air (maybe 80ºF or 90ºF) that was sent into the tubing would obviously be cooled (and even de-humidified!) while passing through the underground tubing loop and the SAME air would come out the other end of the tube, back into the house at as low as around 52ºF. It would quickly and comfortably mix with the existing house air and cool the entire house down, without huge electric bills for operating an air conditioner. (This is again describing the system shown earlier).

Any existing furnace/air conditioning system already has a 'Summer Fan' switch on the wall thermostat. This switch just turns on the blower, without activating the furnace or air-conditioner, and could easily be used to control the airflow through the underground tubes. Alternately, the 'Air Conditioning' switch position on the thermostat could be used. This would then allow the wall thermostat to automatically turn on and off the blower, blowing the house air through the underground tubes as necessary to maintain the desired temperature set on the thermostat! Absolutely automatic! Absolutely identical in usage to traditional air conditioning!

Summer De-Humidification

It turns out that there are even bonus benefits for summertime use, if the tubes are installed in a certain way. The hot summer house air that is sent into the tubes often has very high relative humidity. Both the heat and the humidity make us uncomfortable in the summer. An air conditioner not only cools air but it removes humidity from it as well. (That's why window air conditioners tend to drip.) (It's also why the walls of caves are usually damp and the air down there seems dank.) In the underground tube, that hot, humid air is cooled down by the cool pipe and soil around it. For complicated physical reasons, the RELATIVE humidity gets higher as the air cools. Soon, some of that humidity can condense out on the walls of the tube. (This occurs at a temperature called the dew-point). If the design and planning of the tube system is good, by the time the air has gotten to the house, it is not only cooler, but it has been de-humidified as well! Both of the functions accomplished by an air conditioner are accomplished in a far more natural way. With FAR less electricity and expense involved!

Interestingly enough, this system usually actually lets you control a comfort parameter that normal air conditioning does not, the Indoor Relative Humidity! Massive government tests have determined that the ideal summer indoor conditions are 76ºF dry-bulb temperature (normal temperature) and 40% Indoor Relative Humidity (IRH) (See any ASHRAE Handbook or any psychrometric chart, as below). Store bought air conditioners were designed to accomplish approximately the right IRH as a function of the temperature, so you don't actually have any control.

This system actually does (if you wish it!) Much of the foregoing discussion has mentioned air returning to the house at 52ºF in our examples. This system can actually be used in that way, but that is usually not the ideal situation. If the air passing through the tube actually gets down to 52ºF, then the great majority of its moisture content would condense out on the walls of the underground tubes. That's a desirable goal, but in this case, we're doing TOO good a job! Once that air comes out into the house and becomes warmed to the 76ºF room temperature, it may have too low an IRH for best comfort.

You can use a standard Psychrometric Chart, as below, if you want to plan the humidity. Say you are starting with air that is 85ºF and 60% indoor relative humidity (the lower end of the red line in our example). The Psychrometric Chart immediately shows that there is 0.0155 pound of water vapor in every pound of the air. When it is cooled, it is first a reversible adiabatic process, which keeps the Enthalpy, the energy content of the mixture, constant (the red line in our example to the left and upward, along a line of constant Enthalpy) and the actual amount of water vapor does not change, so the movement is to the left on that Chart. As air is cooled, it can hold less water vapor, so the RELATIVE humidity rises. You can see the red line cross the higher relative humidity percentages in the chart. In this case, you can see that by the time the air is cooled to about 74ºF, the relative humidity has risen to 100%. Up to now, no de-humidification has occurred. But once the relative humidity has gotten to 100%, further cooling requires that water condense out, in this case, on the walls of our underground tubes. On the Psychrometric Chart, continued cooling follows the 100% humidity line downward and to the left (as the green line in our example). If the air is cooled all the way to available 53ºF as in our (Chicago) example, the Chart shows that we would now have 0.009 pounds of water per pound of air. This means that about 0.009 pound of water was removed (during the green line portion). (If the house was 1500 square feet, with 8 foot ceilings, and therefore contained 12,000 cubic feet of air, or around 930 pounds of air, then 930 * 0.009 or about 8 pounds of water was removed, more than a gallon.) When that air becomes heated to the desired room temperature of 76ºF, we go isentropically down to the right on the Chart, to find a resulting IRH of about 20%. That is too low for best comfort, and NOT inside the Comfort Zone of the ASHRAE Comfort Chart (a special version of the Psychrometric Chart). Therefore, conventional A/C units (and our recommendation) only cool the air down to around 60ºF, as we have shown in our example green line. Then, when that air warms up to the desired 76ºF of the house air (as along our blue line), the resulting Relative Humidity is the 40% that the ASHRAE Comfort Chart recommends as most comfortable (in summer).

We (and all conventional A/C systems) have reduced both the air temperature and the Relative Humidity to the desired levels.

So, how would we control the IRH? By controlling how long a time that individual air molecules would be inside the tube system! There are elegant engineering ways of calculating what cfm of blower airflow would provide final airflow temperature, but it is generally easier and more accurate to just measure the (web-bulb) temperature as the air re-enters the house. Or the Psychrometric Chart could be used to determine it. If it is higher or lower, just adjust the air flow cfm through the tube system so that the air returns at that saturation temperature. For locations where the ground temperature is higher than that 60ºF, the house humidity level may be higher than desired, and, under some circumstances, a de-humidifier may be necessary in the house.

It might seem that changing the air flow through the tubes, and therefore the temperature that the air returns to the house, would affect the overall system Btu/hr capability. In general, it doesn't. A LOT of air coming back at 60ºF has as much cooling effect as a lesser quantity of 52ºF air. The actual coolness being delivered is proportional to the PRODUCT of cfm and temperature differential. So, with 80ºF air entering the system, either 1000 cfm at 52ºF or 1400 cfm at 60ºF, would provide the same Btu/hr of cooling. Only the IRH would be different.


In case you are an environmentalist, please note that there is no CFC Freon refrigerants that could affect the ozone layer or otherwise pollute anything. This system represents a version of an elegantly natural, low-tech approach that does the job far better than the high-tech air conditioner does.

Depending on the climate of the house, it might be desirable to arrange this system for primarily or exclusively A/C operation, with little or no concern about winter benefits. In such a situation, there can be additional benefits from looping the tube around so that both ends of it come through the basement walls. Ducts (with dampers) would connect the existing furnace (or air handler) ducts to this path. At whatever point the wall thermostat would call for cooling, that existing blower would turn on and appropriate dampers would move so house air is blown through the underground tubes. This recirculating method has certain advantages, like better control of house humidity, better usage of the available cooling effects (higher net efficiency), and air filtration advantages. A pure recirculating system would have the potential of the super tight house Indoor Air Purity concerns. Probably the ideal solution for a primarily cooling installation would be a primarily recirculating system with a small intake provision for bringing in a little make-up air (for pressurizing the house).


If you already have a full basement, you already have a crude version of this system! You have certainly noticed that such a basement always stays cool in summer (but that it is also often rather humid). The basement floor is actually acting like the walls of the underground tubes we have been describing. House air that flows along that basement floor becomes cool from the coolness of the floor. Just like in the underground tube arrangement, that air also gives up some of its moisture in the process of being cooled, which tends to make basement floors slightly damp and makes the basement sometimes feel humid.

With the underground tubing, the effect of all this is much more prominent, and the moisture that condenses out of the air is collected and removed, very much like a normal air conditioner does.

The basement floor has plenty of "interface area" so short-term performance can be great. If you live in a climate where air conditioning is only needed for a few hours at a time, you could probably get most of the benefits of air-conditioning from just recirculating your upstairs house air through the basement, using the existing house blower/air handler.

If there is NOT thermal insulation under the basement floor, then fairly simple engineering shows the short-term benefit you can get from this cool basement floor. Say the house is 25 feet by 40 feet, so the basement floor is 1,000 square feet. If the ground underneath it is at 52ºF and the house air is at 80ºF, then the "cooling effect" is seen to be (1,000) * 8 * (80-52) = 224,000 Btu/hr! That would be PLENTY to cool your house, and that's why recirculating the upstairs air through the basement can quickly cool the house. Just sending that air through the basement does not actually send all of that air right along the basement floor, so the "basement effect" winds up to be far less than 224,000 Btu/hr, but can definitely be the 36,000 Btu/hr of cooling that your house actually needs. For the record, if you do NOT cause the house air to blow along the basement floor, and leave it to natural convection, instead of 8 in the formula above, ASHRAE says that it is 2.347; also, the basement air is probably nearer to 65ºF instead of 80ºF, so the calculation gives around 104,000 Btu/hr of cooling, again, explaining why basements stay cool! (Keep in mind that this approach does NOT remove moisture from the house air, so there is no de-humidifying effect and a separate de-humidifier would be needed).

However, if your air conditioning needs are for more than a few hours at a time, this approach will soon lose its effect. Gradually, the soil underneath the basement floor will warm up. Since it is a finite volume of soil (basically the size of the house), once it has all warmed up, the cooling effect would be greatly reduced, until an extended period of non-use occurred so the soil could again cool back down. Anyone who has tried to cool their house in this way has noticed the reduction in cooling effect over time.

Any Engineer can solve this Integral Kelvin equation to determine this effect. (By the way, this is the scariest of the equations involved! And the Technical information Packet described below includes a table of solutions for this equation for all practical situations.) If a common, fairly dry, Midwestern soil is under the house, and if this example house needed continuous cooling of 36,000 Btu/hr, the solution shows that the soil a foot below the basement floor would have risen in temperature by 24ºF after just one week! By then, the floor would have been at 76ºF and there would have been no cooling effect at all. Even after just a couple days, the cooling ability would have dropped to about half, because the soil down there would have heated up to around 64ºF. With a more moist common Midwest soil down there, the effect is only half as bad, with a decent cooling effect existing beyond a full week.

A simplistic engineering approach could also be used to roughly estimate long-term performance. In VERY approximate terms, the soil temperature one foot down would probably reflect the overall effect on TWO feet deep of soil down there. One thousand square feet, two feet deep is 2,000 cubic feet or about 200,000 pounds of soil. The specific heat of dry soil is around 0.3, so the heat capacity of this mass of soil is around 0.3 * 200,000 or 60,000 Btu/ºF. If 60,000 Btus are put into that ground, it would rise an average of 1ºF. Since we are talking about putting 36,000 Btu/hr down into that soil, that's 864,000 Btu/day. This implies that the soil would rise in temperature by around 14ºF in a 24 hour period of operation, relatively in line with the solution of the more precise Integral Kelvin equation.

These comments are included to emphasize the need for calculating the long-term performance. Even though a basement floor starts out with incredible short-term cooling capability, in just a few days of use, that cooling effect gets depleted. Larger volumes of soil need to be involved when extended periods of cooling as necessary. The network of underground tubes accomplishes this.


OK! So, YOU don't live near Chicago. YOU live in a much hotter climate. Could it still work? Yup! You probably already found your location on that map we included above. In cities like Los Angeles (68ºF) and San Francisco (64ºF), the deep ground temperature is not 52ºF but it is higher. The configuration has to be designed with more underground tubing, but it will still work like a charm! Even a place like Death Valley amazingly only has a deep ground temperature of around 70ºF)! New York City (54ºF), Seattle (52ºF), Washington DC (56ºF), Denver (52ºF), and such a system would cool excellently. About the only two areas where it is at all complicated is around Miami, where the deep ground is around 77ºF and very southern Texas, where it is about the same. (Farther north in Florida, like Orlando (74ºF) is already simpler and fine!) By the time we get as far north as Atlanta (64ºF), everything is easy! Additional design planning is involved regarding consistently hot areas like Miami, because a lot more underground tubing is necessary, but anywhere else in the USA is a piece of cake!


OK! You already know that you need to pay attention to the three main aspects of it. For a reasonably average sized house, we have mentioned that the tube pattern shown above will be near enough soil for long-term performance and will have enough surface area for short-term performance. We have a couple additional comments regarding the tube diameters.

We had mentioned using nine parallel 4" tubes for the total of about 120 square inches of (total cross-sectional) area for the airflow. Or, for larger houses that need greater airflow rates, 12 parallel 4" tubes for about 150 sq.in., or 16 parallel 4" tubes for around 200 square inches of air-flow (duct) area. We have discovered that some people have read this page and decided to "improve" on it by making one very long air path of a single 4" pipe 500 or more feet long. Well, that WOULD actually work, but it would have a disadvantage. In the same way that firemen use a 3" diameter hose instead of a 1/2" garden hose (to carry far more water for putting out the fire), a single 4" air path would greatly limit the amount of air that could be cooled. True, it would be cooled really well, but there would be very little air flow through the tube, the effect being a lot like the garden hose trying to supply enough water to put out a big fire. The larger area is very important!

Now, if you have 6" pipe available to you locally, roughly five parallel tubes would be necessary to match the air flow through the nine 4" pipes. In that case, the air flow would be fine, but the total tube surface area would be slightly less (making the short-term system performance a little less, and the amount of soil within three feet of a tube would only be 5/9 as much, substantially reducing the long-term performance. So, before you go changing any major aspect of this system, make sure you understand all the consequences of that change!

Four inch PVC drain pipe should be available everywhere. Six inch is nearly as widely available, but usually a lot more expensive.

Some people might fabricate a round or rectangular duct of some sort, and have the branch runs come off of it. A second similar possibility is to just have one large 15" diameter PVC Sewer Main duct come through the basement wall and have all nine separate 4" PVC pipes elbow branch off of it, but that requires more design engineering and probably more expensive large tubes.

We think it is most economical to simply continue all the tubes, in a bundle (3x3 for nine, 3x4 for twelve, or 4x4 for sixteen tubes) back to the building. This should minimize any chance of future leaks at any joints or connections. Better still, once it is all done, IF you discover that you accidentally made one joint badly, where one tube has a leak, that tube could be plugged up (at both ends) to eliminate it from the system!


A recent development regarding this system seems to have arisen in 2007. In relationship with the "whole house free heating system" recently invented here, a control system is appropriate to best keep the interior temperatures of a house as constant as the owner wishes, while still keeping track of the temperatures within the material bin and the heat collection chamber of that system. We have been led to believe that Bluetooth technology (used in many modern communication devices such as cel phones) might be of excellent use. We realize that it probably has just as great a value regarding this air conditioning system as in the heating system!

Specifically, there are apparently furnace wall thermostats which are Bluetooth compatible. We understand that one use of that capability is to have a standard PC (computer) check and record the temperature regularly, as well as recording the minutes of use of the furnace and the conventional air conditioning system. Well, if TWO such thermostats were used, one inside the house as normal, and the other down inside one of the tubes, then the PC could record and track some really useful data. In the hours that NO airflow was going through the tubes, then the temperature readings would record how quickly the underground tube system was recovering from previous usage. In other words, making a record to be able to predict how quickly the system would be able to regain cooling ability after a very hot afternoon! This would essentially be the LONG-TERM performance guide. WHILE the air was going through the tubes, and knowing the current temperatures of the house and the tubes, the gradual increase in the air temperature inside the tubes would be an indication of SHORT-TERM performance. This might be a valuable addition to this type of installation. Therefore, if there are people out there with good knowledge of Bluetooth technology, and/or access to those Bluetooth-compatible wall thermostats, we encourage experimenting! And whether results are useful or not, please let us know so that we can inform others of what seems to work and what does not.


We would have liked to include all specifics in this page, but there are quite a few variables that can affect the performance of this system. (You probably haven't been too thrilled with the engineering info we've used here!) For example, two identical houses, a mile apart, could need extremely different systems, if one was over very dry sand and the other was in a marshy area. In this case, the necessary area of pipe is different by a factor of four! Also, the size and shape of a yard, the climate, the house size, and the soil type all can affect the best choice of tubing diameter, so we cannot even generalize there! Sorry! You need to either do the math yourself or have us provide the equations in the Technical Packet or over-estimate how much pipe you will need.

Ever since we first started offering this system for free in late 2000, we have also offered a Technical Packet, too. We have always asked people to make a Donation to ANY Charity or Church of their choice, anonymously, of $250, for a collection of equations, formulas, charts, (pre-calculated solutions of that Integral Kelvin equation!), and a lot of additional guidance regarding designing of the tube sizes, materials, lengths, and a bunch of general suggestions. If you happen to be or to know a Thermodynamics Engineer, he could probably do all of this for you and you wouldn't have to pay anyone anything! The planning involves the size of the house, the climate it is in, its estimated heating/cooling load, the number of members of the family, the size and shape of the yard available, the type of soil, etc., to determine the diameters, configurations, patterns, depths, etc. of the components of this system. Many variables are sometimes involved, including mountains, lakes, forests, and other local conditions.

For many climates, the necessary yard area that would have to be dug up for this network of tubes might only be 50 feet square! If you followed our "basement" discussion, this area of tubes would involve a volume of soil of about 56 feet square (about 3,000 square feet) and about double the vertical depth of soil (because the basement "hole" is not there). In other words, even this moderate area of yard could be used to supply around SIX TIMES the long-term cooling effect of the basement floor example. (3,000 * 4 or 12,000 cubic feet of soil instead of 2,000). In hot climates, a larger area of yard would obviously be necessary.

We don't want to LOSE money as a result of providing this offer! It isn't fair when many people ask for a lot of free engineering as well, seeming to have the attitude that we are somehow RESPONSIBLE to try to "sell" this system! IT IS FREE, with all the necessary information provided to you in this and linked pages. And even if you have doubts and insist on duplicating the calculations and logic for yourself, the Technical Packet even enables you to do that. It is fairly time consuming to do all of the necessary calculations and Engineering, especially when thousands of people expect this to all be done for them. We have no problem with a MODERATE number of questions, and we do our best to find the time to answer all of them, within reason. (But some people consider it reasonable to ask fifty to eighty very specific technical questions!) We encourage you to find a local Civil Engineer who could equally do the math. We created this Engineering presentation because we have already done a LOT of research and collected all the useful stuff in that collection of information. Prior to our deciding to provide this for free after watching the California energy crisis late in 2000, we had fully Engineered (and used) this system as a sub-system meant as part of of the NorthWarm Version 1 100% solar house heating system. We are hopeful that the $250 required Anonymous Donation for the Technical Packet (which is generally not even actually necessary) would not cause a hardship on anyone for that information.

By the way, we really LIKE the fact that many thousands of people, world-wide, have indicated that they planned to install this system. But just as much, we like the fact that, so far, in mid-2007, over 4,900 people have requested the Technical Packet. Assuming that they each fulfilled their word of Anonymously Donating $250 (US) to some Charity or Church, that means that those people have contributed over a million total dollars, all anonymously, to many different worthy causes! We REALLY like that! Can you imagine a Soup Kitchen that finds an envelope of $250 in their mailbox one day? Does it get any better than that?


Doing This Without Our Help

Water Condensation, Fungus, Etc.

IF you choose to do this without our guidance, PLEASE be aware that there is a tendency to accumulate puddles of moisture in the tubes, and if you don't plan it right, and that could represent a breeding-grounds for moss, fungi and other things. Some of the things that could grow there can be bad. Remember that Legionnaire's Disease was caused by condensation accumulations from conventional air conditioning equipment and that it was a bad situation. There are similarities to be careful about.

You know how house rain gutters slightly slope, so they drain? Just an inch or two in a ten-foot length? That MUST be done for these underground tubes. NO corrugated tubing should be used, because it would trap such condensed moisture in lots of little puddles. The tubing should have a smooth interior. Since it is relatively hard to confirm that a minimal slope has no low spots (far harder than for gutters), it is generally a good idea to provide a somewhat greater slope than normally used in house gutters. The slope should probably go downhill along the direction of the airflow, so the moving air would tend to push the water along. This could terminate in a central condensate collection point in the tube system (possibly with an automatic sump pump), or it could continue all the way back into the house, where the water would be collected and then sent down a sewer drain. These considerations would eliminate any danger of a puddling or bacteria problem in the tube system.

There is actually an alternative available if you are not interested in the de-humidifying ability of this system. You could install a much stronger blower! The air would be cooled by passing through the underground tubes, so you would get the cooling part of the air conditioning. But if the air passes through the tubes so fast that it can never get cooled below its dew-point, then no condensation could occur, and you would eliminate the de-humidifying, which means no moisture would be removed from the house air and so no condensation droplets could ever form inside the tubes. We think this is foolish, in giving up half of the benefits of air-conditioning (the reduction of humidity), and we strongly encourage you to just make sure of adequate slope in all the tubes.

We have noticed that a lot of people are very concerned about even the possibility of accidentally not providing good drainage of the (hidden) underground tubes, and thereby having some sort of health consequences. We are confident that proper sloping for good drainage can absolutely eliminate this concern, however we have figured out a variant of this system for people who are really worried about this. The variant does not ever send the house air underground, and the condensation of humidity which occurs is exactly the same as with all other central air conditioners. This variant involves TWO heat exchange processes, which causes it to be slightly less efficient, but it certainly cannot have any underground puddles causing things to grow in them! You need to generally understand the system described above, in order to follow the differences described in water-filled variant.

NOTE: Before you go digging, make absolutely sure that no easements are across the property. You DEFINITELY do not want to dig into high voltage electrical cables or gas mains or water mains!


From an engineering point of view, remember that the three main considerations are (i) the heat transfer between the soil and the air passing through the tubing, (ii) the total mass of soil participating in this system, and (iii) the total airflow path area inside the tube system. It often works out best (depending on soil type and moisture content) that several parallel smaller tubes be used rather than one large one, because of these considerations. Just think about how a septic field is designed to see why, or try the engineering calculations for different configurations. You will quickly see that you can substantially increase tube-soil surface area and the total mass of participating soil by running parallel tubes six feet apart. The example we discussed earlier represents a very practical system for many mid-sized houses. (This is the sort of additional guidance and insight we include in the Technical Packet).

But, let's say you don't get our help and you happen to not bury enough pipe. Well, even in that case, you come out fine, because the system would do much of the air conditioning (depending on how well you planned the piping) and will greatly reduce your air conditioning bills anyway. So, even if you somewhat mess up by not doing any preliminary engineering, you still win!

Hot Climate Applications

We have had many people ask about using this system in south Florida or southern Texas, where the climate is extremely hot. We have already mentioned above that, in such climates, the ground is not cool enough to cause sufficient condensation of humidity in the air, so a house de-humidifier would absolutely be necessary.

The trenches should be as deep as can be managed (without danger to workers regarding collapses!), because in very extended hot weather, the top several feet of soil can get heated by a number of degrees. There is a VERY simple way to know how serious a problem this might be, regarding trench depth. On an August afternoon, after a long stretch of hot days, turn on a house water faucet of the Cold water, but from a MUNICIPAL supplied water source. That water gets distributed to all the houses by a pattern of water main distribution pipes, generally around 3 feet deep. So, after you let that Cold water run for about a minute, accurately measure its temperature. Whatever that temperature is, is probably very close to the temp of the three-foot-deep soil at that moment.

If it is 70ºF or below, the air-based system described above should be able to provide decent cooling (but with a larger underground tube pattern, maybe double in size). But if that water comes out at around 70ºF or above, then the benefits might be limited. But there are still some possibilities!

If you can dig a lot deeper, you can reduce the effects of the gradual summer heating of the soil. It is well known that at a depth of around 12 feet there is only one or two degrees of annual temperature change, and that it is actually delayed by several months to essentially completely eliminate the effect. At 8-foot depth, the delay is around two months and there are only a few degrees of seasonal difference at that depth. Shallower means that the seasonal differences are greater, and that the heat gets down there in weeks rather than months. We initially suggested the three- to four-foot depth for the tubes, for applications in MODERATE climates, and because fairly simple and inexpensive ditch-digging trenchers can be rented by the hour or day to do that. For deeper trenches, more involved planning and more expensive equipment needs to be involved.

Both of our main suggestions then involve the EXACT same buried tubes, but now filling them with water (as more fully described in our separate page on the water-filled version, linked a few paragraphs above). The simplest is to then use it IN COMBINATION with an existing central A/C. Normally, existing hot house air might be at 90ºF when it gets drawn into return air ducts to be blown through the A/C coil again, and the A/C then has to do a lot of work cooling that air down. Think now of installing a standard car radiator (or a more sophisticated and expensive equivalent) in that return duct, just before the A/C coil. The relatively cool (70ºF???) water from the underground tubes is run through the radiator with a small pump. As the house air passes through that radiator, it gets cooled! On mildly hot days, that cooling might be enough that the actual A/C does not even need to turn on! But on extremely hot days, the house air may not be cooled sufficiently by the radiator, and so the conventional A/C might need to turn on. This is still good! The conventional A/C would have a far easier job, as the air getting to it is already greatly cooled. AND it would probably have to run for far less time. Both effects would greatly reduce the electricity bills due to A/C.

The other main suggestion is more complex to install. It is also a water-filled system, but instead of just small tubes being underground, there would be either LARGE pipes or even a large tank buried as deep as possible! We will use here an example of a 1200-gallon concrete septic tank, placed in as deep an excavation as possible (here suggested, 10 feet deep). That tank would be carefully sealed shut (lid and body, and also around the connection holes) so there were never any leaks.

Here is the reasoning for that approach. Twenty-four hours every day, that tank would conduct heat away, including at night. The primary extreme heating of the house is during the afternoon, when maximum A/C is needed. The 1200 gallons of water in the tank should then generally be able to cool back down to around the 70ºF by every morning. That much water weighs around 9,000 pounds, so if the A/C heat removal from the house during the hot hours of that day were, say 90,000 Btu, that tank water would still only get up to around 80ºF and still be able to provide some cooling effect to even hotter house air! (During that night, it would cool back down!) We note that this only represents around 30,000 Btu/hr of full cooling for three hours, but we see it as better than nothing! Also, if THREE such tanks were buried in different parts of a yard, then they would have available as much as 270,000 Btu of total cooling, which might be enough for most houses!

Note that these water-filled systems have the water permanently trapped inside, which eliminates any possibility of the mold and fungus that could occur if an air-filled system did not have good drainage slopes. But the water-filled systems are slightly less efficient, because they require TWO heat-exchanges (tube wall to water, then water/radiator to house air) where the air-filled systems only require ONE heat-exchange (buried tube wall directly to house air). Also, before sealing it in, the trapped water should be given some pool chemicals or the equivalent to reduce future growths or contaminants.


This system was and is a part of the Solar Version 1 System. It may separately be used for either existing homes or buildings or for new construction.


This "gift" we are presenting to the American people is related to a more complex variation which could be used for buildings that are still in the planning stage. The underground air conditioning described here is for either existing houses or new construction. The second concept applies these same heat flow Engineering considerations to provide STORAGE of very large amounts of EITHER heating or cooling, but it can only be considered for new construction. Relatively few applications would need the second concept for air conditioning, except possibly in extremely hot climates. It is more intended as providing heat for a house for at least half of a winter without needing gas or oil or electricity (except for a blower) That variation involves a LOT of application specific Engineering, which we would have to provide, so that cannot be provided for free. Sorry! It is at: Months of Free Heating or Cooling!.


Back to the underground tubes system described in this web-page!

Depending on the local cost for usage of a backhoe, or if you happen to love to shovel(!?), the installed cost of this system may be less than a conventional central air conditioning system. Depending on the climate and house size, the necessary pipes could cost around $500. Depending on how much a backhoe or trencher costs in your area, that might also be around $500. This suggests that some installations could realistically be put in for well under $2,000. If you can put in LOTS of narrower tubes, a Ditch Witch Model 1820 trencher can make 4 foot deep trenches for around $220 rental per day. And you essentially eliminate ALL those huge summer air conditioning electric bills! And you get significant energy savings in winter, too! Forever!

In nearly all cases, the existing furnace blower or air handler, and wall thermostat could be used, so there's virtually nothing necessary except for the tubing and the trenching. And there's nothing bizarre about operating the system, either, since the normal wall thermostat would be used exactly as before.

We believe this to be a feature that nearly all houses could benefit from. Considering recent large price hikes for electricity and natural gas, we felt it appropriate to present it as a separate system, where it has always been considered a relatively minor part of the full Solar Heating System.

Even if you have already paid for an existing central air conditioner, this intake arrangement could quickly pay for itself in combined heating and cooling savings. Just do the cost calculations suggested above to find out what YOU might save. And, even if you happen to be in a climate, like Miami, where you might feel it too involved and costly to bury all the necessary piping for an entire system, any size system that you would install would greatly reduce your air conditioning electricity costs.

Since we're basically telling you how to generally do this, for free, we feel it's fair to ask a single favor in return. If you happen to live in or near California, and you install this system, please call ANY local newspaper, radio or TV reporter to look at what you did. We don't really care if we get any credit in the matter, but it's important to get the word out to all California homeowners that they each have a way to greatly reduce their summer electric bills. And, if enough of them actually do that, collectively we might help avert a big summer problem of blackouts out there. In the process of this, you might even get yourself on TV, if that's important to you! It might seem surprising, but WE don't want any publicity from this effort at trying to help California deal with a big problem. We just believe that we have a grass-roots solution for it, and that people should help one another.


In addition, this system represents an obvious solution to the recent flurry of legislation that is trying to deal with Indoor Air Quality issues. Bringing additional air in through our (winter) warming tube to pressurize the house would only have about 1/4 (depending on climate) the winter heating load increase of currently favored approaches (that just directly bring in outside air). This could even allow the legislators go totally over the top and to insist on drilling one-inch diameter holes in the walls of the house, without spectacularly increasing heating costs! That, and a continuous source of pressurizing (52ºF) air from our tube, would certainly purge stale and polluted house air! (But we hope they won't do that!)


OK. Many thousands of people seem to act as though we are SELLING something here, and they DEMAND that we provide names and phone numbers of people who have installed the underground tubes system! They seem to overlook that we are GIVING this technology away, as a gesture of compassion and community. Also, with countless thousands of people examining these web-pages, we learned long ago that kind people who are willing to tell people about their experiences are immediately overwhelmed by constant calls, day and night, and such people have quickly asked us to remove their names from such a generous offer!

However, there are some known examples of SIMILAR installations:


Hi, thanks for your discussion of earth tubes. I wish it was available when I built my house but I am now referring everyone here in Australia to your site when they visit and want more information.

It may be of interest to you that I built a 700 m2 (6,500 square feet, extremely large) house near Sydney with six 250mm (10 inch) cool tubes. With the help of the University of Athens SUMMER programme I modelled my site and calculated that I would get 82% of my cooling in lines only 30 metres (100 feet) long. I buried them in a radial spread 3.5 metres (10 feet) deep in clay which has a year round 18.2ºC (65ºF) subsoil temperature. I have abundant cooling, virtually no refractory period and can keep the house at any temperature from 24ºC (75ºF) upwards effortlessly all year round. You will appreciate that with a climate similar to Houston Texas, air conditioning a huge house for an overall cost of $15.60 a year attracts many visitors.

I'd add to your summary that with high dehumidification, molds etc are a real problem but with a slope away from the house to a drainage sump I then use slow release chlorine tablets which knock this stone dead. When working gives a very faint ozone smell in the house which is quite pleasant. Not sure what the equivalent brand is in the US but marketed by Amatil for use in pools. A handful once a season does the job.

Thanks once again for your excellent summary.

Jim McKnight

(Note that he sloped the tubes AWAY from the house and therefore had condensation water accumulate at the outer ends of his star pattern of tubes, where he then has to sump-pump it out, meaning there are ALWAYS puddles out there. Our approach is very different, where we want the tubes to always slope slightly downward, as with rain gutters, and so the moving air tends to push along any droplets of condensation all the way through to a collection drain just inside the house.)

(His house is five times the size of most American houses, so he used larger diameter tubes and longer. He also buried them deeper, definitely a good idea, but really deep digging like that can be rather expensive, and our description here was to provide a reasonably economical installation. Our thoughts are that if an owner liked the benefits but would like a little more cooling, he could always later bury some additional tubes in a different part of the yard.)


Early in 2006, there is a lot of publicity about the new government building for the country of Wales, in Great Britain. It is an extremely large building, but it apparently has a number of air tubes that extend well below the building, for benefit of natural air conditioning and heating. It is a variant of the concept presented here, but the functioning is very much the same.


The US Government has a web-page: EERE Consumer's Guide: Earth Cooling Tubes, about the general subject. Unfortunately, that web-page refers almost entirely on a limited amount of experimentation done in the early 1980s, and the references cited are therefore very outdated. Several years ago, the text of that page was incredibly negative toward the concept, but the author (un-named) was clearly not knowledgeable in Heating or Engineering, and the web-page then was clearly the equivalent of a school term paper based entirely on some documents that had been found. The same documents are still the basis of that web-page, and it is not clear that the more recent editors have any more expertise in HVAC or Engineering, but at least the tone of the web-page is less negatively biased.

The recent editors seem to have adopted a few concepts from our presentation but also still rely on some incorrect conclusions of the early 1980s. The main point regarding that web-page is that it has now been altered to see some value in the concept, although they still give bad guidance regarding the diameter of the tubes, and their web page now even admits that they have limited information! One great problem with nearly all of the installations of the 1980s was that they were single-pass, open-loop systems. Such systems were doomed to perform poorly, just as a single-pass, open-loop central furnace would do! Any well designed furnace or air-conditioning system gets much of its benefits from recirculating the house air over and over, therefore only having to slightly change its temperature, rather than forever having to heat or cool every cubic foot of outdoor air!

It is frightening that the government web-page referred to aluminum tubes as acceptable! ANY Engineer knows how rapidly aluminum corrodes in contact with damp soil due to electrolysis! NO reputable Engineer would place ANYTHING that was aluminum in direct contact with damp soil! (This is an example of weaknesses in the government's web-page!)

But they seem to have added comments (possibly from our site) regarding different types and moisture contents of soils and some comments about condensation/growth issues, which didn't use to be in that web-page.


We have a gripe! A large number of people do not seem familiar with the story about not looking a gift horse in the mouth! (When someone GIVES you a horse, it is not very polite to immediately attempt to determine the quality and health of the horse!)

This presentation is a GIFT! We didn't try to SELL you anything, or even try to FORCE you to make any decision! This information is LOOOOOONG because we tried to provide sufficient information and logic so that you might get a basic understanding of the concepts behind it, and that we attempted to include a reasonable amount of information regarding actually installing it.

We get a lot of notes that complain about how long this is. Sounds somewhat like Gift Horse to us! But a large number of people INSIST that we provide the names and addresses and phones of people who have installed such systems! We feel that is incredibly offensive! How dare people insist on bothering people (WITHOUT then being expected to pay any money for any product!) just because they happen to not understand the value of something? Hey, go ask for the pedigree papers on that Gift Horse!

Other people seem amazed that these web-pages do not include testimonials of people who installed the system. Again, if we were trying to SELL such a system, that would make complete sense, in trying to convince you to want to give money to us! But since that is not the case, we really see no reason at all to feel any need to provide such testimonials. Do you really believe all those TV ads where people claimed to have lost 80 pounds in three weeks while eating everything they like?

If you choose to find no value in these pages, fine! You are free to do that. If you are not sure, you are free to hire some local Civil Engineer or Thermodynamicist to examine these pages to tell you whether or not there is any value here. But we have pretty much gotten tired of responding to Gift Horse e-mails, and probably will never again respond to such notes!


E-mail to: Public1@mb-soft.com


The Solar heating systems:



Links to energy-related pages in this Domain:
Global Warming Calculated by a Physicist
Global Warming and Climate Change - Possible Physics Solutions
Unlimited Hot Water FOR FREE, while Solving Global Warming!
Heat Your Whole House FOR FREE, while Solving Global Warming!
Current Energy Resources in Existence (Scary!)
Making all (Black) Asphalt Roads, Rooftops and Parking Lots White can help with Global Warming!
Global Warming Issues Regarding HEAT Sent into the Atmosphere
Global warming Issues Regarding Carbon Dioxide, and Sealevels Rising
Hydrogen as an Fuel-source Replacement
A 100%-Solar Home Heating System
Solar Electricity from PV Photovoltaic Cells
Batteries or Hybrids as an Fuel-source Replacement
Wind-Power for Making Electricity

The Earth's Rotation as a Source for Energy
Waste Nuclear Power For Making Electricity And Heat?
The Physics of Efficiency In Electric Power Plants
Individual Ways of Reducing Your Energy Usage
Methods of Storing Energy for Later
How Much Energy Comes From the Sun? And Why is there Global Warming?
How does the Sun create so much energy?
Inventions Which Might Help Deal With Coming Energy Catastrophes
An Invention to Efficiently Make Electricity from Solar
Enormous Heating of the Atmosphere by the Alaska Pipeline
Air Conditioning without Huge Electric Bills and without Freon
A Method of Storing Summer Heat to (Nearly) Entirely Heat a House all Winter
An Extremely Highly-Efficient (and Fast, 200.0 mph) Transportation System for People and Products
The Sophisticated Woodstove I Invented in 1973

The Physics of Wood as a Heating Fuel
Why is the North Pole Heating Faster than the rest of the Earth?
A Possible way to greatly reduce Aerodynamic Drag of Airplanes






E-mail to: Public1@mb-soft.com

Solar Heating